Heat pumps · Error codes · MasterTherm
AL12MasterTherm

AL12 on a MasterTherm heat pump: Low Pressure HP side - too low pressure on high-pressure side of refrigerant circuit

Short answer

On a MasterTherm heat pump, AL12 means: Low Pressure HP side - too low pressure on high-pressure side of refrigerant circuit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 1 source

What it means

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

The manual says: Low Pressure HP side - too low pressure on high-pressure side of refrigerant circuit.

Part involved: refrigerant circuit (charge).

When it shows: Control action: See AL01, AL02 (AL08 in pAD/pGDx air-water tables). Operator guidance: Always call service.

Likely causes:

  • Low refrigerant quantity in the circuit (alarm prevents compressor running with low charge).

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

The manual says: Low Pressure on HP side.

Part involved: refrigerant circuit.

When it shows: Control action: See AL01, AL02. Operator guidance: See AL01, AL02.

Likely causes:

  • See AL01/AL02; low refrigerant quantity.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Resets automatically after the minimum compressor off time (~6 min) if the same alarm occurs fewer than 3 times per compressor operating hour.

Manual reset: After 3 occurrences in 1 compressor operating hour the unit is blocked (ALARM key lit steadily); manual reset by pressing ALARM key on the alarm display (pGD) or RESET on pGDx Alarm Management.

What you can check

  • Read and note the alarm (ALx code/text) and the alarm counter shown on the pGD/pGDx display.
  • Check the heat pump breaker/isolator in the consumer unit is on.

What the engineer will check

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

  • Leak test, check refrigerant charge.
  • Check setpoint A75.

Who to ask for: heat pump service engineer (refrigeration/controls).

Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

  • Leak test / refrigerant charge check.

Who to ask for: ground source heat pump engineer (refrigeration/controls).

Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026