Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

63 codes

CodeMeaningStops?Homeowner check?
Ba
T4 out of operation range
Not statedYes
bH
PED PCB failure
Not statedYes
C7
High temperature protection of inverter module heat sink
Not statedYes
CD
Compressor module fault (L1E-L- family per table)
Not statedYes
CL
Water pump communication wire fault
Not statedYes
E0
Water flow fault (10 times E8)
Not statedYes
E1
Power fault
Not statedYes
E2
Communication fault between wired controller and indoor unit
Not statedYes
E3
Hydro-box water outlet temperature sensor (T1) fault
Not statedYes
E4
Water tank temperature sensor (T5) fault
Not statedYes
E5
Outdoor unit heat exchanger temperature sensor (T3) fault
Not statedYes
E6
Outdoor unit ambient temperature sensor (T4) fault
Not statedYes
E7
Balance tank temperature sensor (Tbt) fault
Not statedYes
E8
Water flow fault
Not statedYes
E9
Compressor suction line temperature sensor (Th) fault
Not statedYes
EA
Compressor discharge line temperature sensor (Tp) fault
Not statedYes
Eb
Solar panel temperature sensor (Tsolar) fault
Not statedYes
EC
Water tank temperature sensor (T5_2) fault
Not statedYes
Ed
Hydro-box plate heat exchanger water inlet temperature sensor (Tw_in) fault
Not statedYes
EE
Hydraulic module EEprom failure
Not statedYes
EL
Communication fault between hydraulic module and MH-kit
Not statedYes
F1
DC bus low voltage protection
Not statedYes
F6
EXV fault
Not statedYes
FC1
TL temperature sensor fault
Not statedYes
H0
Communication fault between hydro-box and outdoor unit
Not statedYes
H1
Communication fault between main control board and inverter module board
Not statedYes
H2
Plate heat exchanger outlet (heat) refrigerant temperature sensor (T2) fault
Not statedYes
H3
Plate heat exchanger inlet (heat) refrigerant temperature sensor (T2B) fault
Not statedYes
H4
Three times L1 protections
Not statedYes
H5
Room temperature sensor (Ta) fault
Not statedYes
H6
DC fan motor fault
Not statedYes
H7
AC voltage protection
Not statedYes
H8
High pressure sensor fault
Not statedYes
H9
Zone 2 water flow temperature sensor (Tw2) fault
Not statedYes
HA
Hydro-box plate heat exchanger water outlet temperature sensor (Tw_out) fault
Not statedYes
Hb
3 times 'PP' protection
Not statedYes
Hd
Communication fault between master unit and slave unit
Not statedYes
HE
Communication error between main board and thermostat transfer board
Not statedYes
HF
Outdoor unit EEPROM fault
Not statedYes
HH
10 times H6 in 120 minutes
Not statedYes
HP
Low pressure protection in cooling mode
Not statedYes
JCD
Fan module fault (J1E- family per table)
Not statedYes
L0
Module protection (P6 group)
Not statedYes
L1
DC generatrix low voltage protection (P6 group)
Not statedYes
L2
DC generatrix high voltage protection (P6 group)
Not statedYes
L4
MCE malfunction (P6 group)
Not statedYes
L5
Zero speed protection (P6 group)
Not statedYes
L7
Phase sequence error
Not statedYes
L8
Speed difference > 15 Hz between the front and the back clock (P6 group)
Not statedYes
L9
Speed difference > 15 Hz between the real and the setting speed (P6 group)
Not statedYes
P0
Heat pump system low pressure protection
Not statedYes
P1
Heat pump system high pressure protection
Not statedYes
P3
AC current protection
Not statedYes
P4
Compressor discharge temperature too high protection
Not statedYes
P5
|Tw_out - Tw_in| value too high protection
Not statedYes
P6
Inverter module protection group (sub-codes L0, L1, L2, L4, L5, L8, L9)
Not statedYes
P21
Low pressure sensor fault
Not statedYes
P27
Pressure sensor reverse insertion protection
Not statedYes
Pb
Anti-freeze mode
PartlyYes
Pd
Condensing temperature too high protection
Not statedYes
PE
Water pressure sensor fault
Not statedYes
PF
Insufficient discharge superheat
Not statedYes
PP
Tw_out - Tw_in unusual protection
Not statedYes