P1Ferroli

P1 on a Ferroli heat pump: Heat pump system high pressure protection

Short answer

On a Ferroli heat pump, P1 means: Heat pump system high pressure protection. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the OMNIA LIFE M monobloc R290

The manual says: Heat pump system high pressure protection.

On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)

The manual says: High pressure switch protection.

Likely causes:

  • Low water flow / air (heating, DHW).
  • Water pressure < 0.1 MPa.
  • Refrigerant overcharge.
  • EXV locked.
  • Cooling: coil cover not removed / coil dirty.

On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)

The manual says: High pressure switch intervention.

Part involved: high-pressure switch.

Is it safe?

On the OMNIA LIFE M monobloc R290

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: Manual 13.3: reset the unit by powering it off and on; if resetting is invalid contact the local dealer.

On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: Manual (13.4): reset the safety by turning the unit OFF and back ON; if unsuccessful contact your local dealer.

On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: Manual (sect. 10.3): reset the safety device by turning the unit OFF and back ON; if unsuccessful contact the local dealer.

What you can check

  • Check the outdoor unit is not blocked by leaves, debris or snow and has clear airflow.
  • Note the code shown on the user interface and contact the installer/Ferroli service.
  • The manual says the safety can be reset by switching the unit OFF and back ON; if the code returns, do not keep resetting - call the installer.

What the engineer will check

On the OMNIA LIFE M monobloc R290

  • Diagnose per Ferroli/controller service information (Annex G gives description only; the wired controller shows the explanation).
  • R290 refrigerant-circuit work: flammable refrigerant, competent/certified engineer only.

Who to ask for: heat pump engineer (R290).

Certification: R290/flammable refrigerant competence for refrigerant work.

On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)

  • Low water flow / air (heating, DHW).
  • Water pressure < 0.1 MPa.
  • Refrigerant overcharge.
  • EXV locked.
  • Cooling: coil cover not removed / coil dirty.
  • Refrigerant-circuit diagnosis (F-gas).

Who to ask for: heat pump / refrigeration engineer.

Certification: F-gas certification for refrigerant circuit work.

On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)

  • Refrigerant-circuit diagnosis (F-gas).

Who to ask for: heat pump / refrigeration engineer.

Certification: F-gas certification for refrigerant circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026