L0 on a Ferroli heat pump: Module protection (P6 group)
Short answer
On a Ferroli heat pump, L0 means: Module protection (P6 group). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.
Reviewed 23 September 2026 · 2 sources
What it means
On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)
The manual says: Module protection (P6 group).
Likely causes:
- Check system pressure.
- Compressor phase resistance.
- U/V/W sequence inverter-compressor.
- L1/L2/L3 inverter-filter board.
- Inverter board.
On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)
The manual says: Inverter module protection.
Part involved: inverter module.
Is it safe?
On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)
| Does the heat pump stop? | Not stated |
|---|---|
| Engineer needed? | Yes |
The manual does not say whether the heat pump stops.
Manual reset: Manual (13.4): reset the safety by turning the unit OFF and back ON; if unsuccessful contact your local dealer.
On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)
| Does the heat pump stop? | Not stated |
|---|---|
| Engineer needed? | Yes |
The manual does not say whether the heat pump stops.
Manual reset: Manual (sect. 10.3): reset the safety device by turning the unit OFF and back ON; if unsuccessful contact the local dealer.
What you can check
- Check the consumer-unit breaker/isolator for the heat pump is on.
- Note the code shown on the user interface and contact the installer/Ferroli service.
- The manual says the safety can be reset by switching the unit OFF and back ON; if the code returns, do not keep resetting - call the installer.
What the engineer will check
On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)
- Check system pressure.
- Compressor phase resistance.
- U/V/W sequence inverter-compressor.
- L1/L2/L3 inverter-filter board.
- Inverter board.
Who to ask for: heat pump engineer.
Certification: Electrical competence for board/wiring work.
On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)
Who to ask for: heat pump engineer.
Certification: Electrical competence for board/wiring work.
What you might notice
Sources
- OMNIA M 3.2 mod. 4-16 - Reversible heat pumps for outdoor installation with DC inverter compressor - installation/owner manual (IT-EN...) ↗ · Cod. 3QE47740 - Rev. 02 - 11/2023 · page 76 · Reviewed 23 September 2026
- OMNIA S 3.2 - Installation, use and maintenance manual (IT-EN-ES-PT-FR-DE-NL) ↗ · Cod. 3541V942 - Rev. 01 - 06/2026 · page 126 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026