H3 on a Ferroli heat pump: Plate heat exchanger inlet (heat) refrigerant temperature sensor (T2B) fault

Short answer

On a Ferroli heat pump, H3 means: Plate heat exchanger inlet (heat) refrigerant temperature sensor (T2B) fault. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the OMNIA LIFE M monobloc R290

The manual says: Plate heat exchanger inlet (heat) refrigerant temperature sensor (T2B) fault.

On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)

The manual says: Refrigerant gas temp. sensor (T2B) fault.

Likely causes:

  • Sensor connector loose or wet.
  • Sensor failure (check resistance).

On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)

The manual says: Refrigerant gas temperature probe fault (T2B).

Part involved: T2B probe.

Likely causes:

  • Probe resistance.
  • Connector disconnected/wet.
  • Faulty probe.

Is it safe?

On the OMNIA LIFE M monobloc R290

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: Manual 13.3: reset the unit by powering it off and on; if resetting is invalid contact the local dealer.

On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: Manual (13.4): reset the safety by turning the unit OFF and back ON; if unsuccessful contact your local dealer.

On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: Manual (sect. 10.3): reset the safety device by turning the unit OFF and back ON; if unsuccessful contact the local dealer.

What you can check

  • Note the code shown on the user interface and contact the installer/Ferroli service.
  • The manual says the safety can be reset by switching the unit OFF and back ON; if the code returns, do not keep resetting - call the installer.

What the engineer will check

On the OMNIA LIFE M monobloc R290

  • Diagnose per Ferroli/controller service information (Annex G gives description only; the wired controller shows the explanation).

Who to ask for: heat pump engineer (R290).

Certification: Electrical competence.

On the OMNIA M 3.2 monobloc R32 (4-16 kW and 18T-30T)

  • Sensor resistance/connector checks, replace sensor.

Who to ask for: heat pump engineer.

Certification: Electrical competence for board/wiring work.

On the OMNIA S 3.2 split (wall-hung hydronic unit + OMNIA UE 3.2 outdoor)

  • Probe resistance and connector checks (dry wet connectors, waterproof tape), replace probe.

Who to ask for: heat pump engineer.

Certification: Electrical competence for board/wiring work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026