Tigo Energy inverter error codes

Tigo Energy · A niche brand in the UK. 36 codes across 2 product families, each taken from the manufacturer’s manuals. Tigo Energy technical support ↗

Find a Tigo Energy engineer →36 codes · reviewed 24 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

36 codes

CodeMeaningStops?Homeowner check?
blinking-green-and-yellow
PV-OFF mode activated manually via connected switch/relay - similar to rapid shutdown (string DC voltage ceases).
PartlyYes
dark-or-unlit-led
System in rapid shutdown / no 12 V power to CCA.
PartlyYes
flashing-green
EI app connected to CCA by Bluetooth / data transfer in progress.
NoYes
flashing-yellow
Discovery in progress (detecting TAPs, configuring optimiser radio); also during optimiser replacement.
NoYes
IE001
TZ Protect Fault (Over Current Fault). Tigo suggestion: Wait; disconnect and reconnect PV and batteries; contact Tigo.
YesYes
IE002
Grid Lost Fault (Grid Lost Fault). Tigo suggestion: Wait for power to return; check grid voltage in range; (detailed article: inverter POWER blue LED off; check AC breaker and main breaker on).
YesYes
IE003
Grid Volt Fault (Grid Voltage Fault). Tigo suggestion: Wait for reconnection; check grid voltage.
YesYes
IE004
Grid Freq Fault (Grid Frequency Fault). Tigo suggestion: Wait for reconnection.
YesYes
IE005
PV Volt Fault (PV Voltage Fault). Tigo suggestion: If string voltage >600 V DC shut down and troubleshoot strings.
YesYes
IE006
Bus Volt Fault (Buss Voltage Fault). Tigo suggestion: Press ESC to restart; check Voc <600 V DC.
YesYes
IE007
Bat Volt Fault (Battery Voltage Fault). Tigo suggestion: Check battery input voltage.
YesYes
IE008
AC10M Volt Fault (Grid Voltage Fault). Tigo suggestion: Returns to normal when grid normal.
YesYes
IE009
DCI OCP Fault (DCI Overcurrent Protection Fault). Tigo suggestion: Wait for normal.
YesYes
IE011
SW OCP Fault (Software Detection of Overcurrent Fault). Tigo suggestion: Wait; if not, shut down PV, battery and grid and restart inverter.
YesYes
IE012
RC OCP Fault (Overcurrent Protection Fault). Tigo suggestion: Check DC input and AC output impedance; wait.
YesYes
IE013
Isolation Fault (Insulation Fault). Tigo suggestion: Wait; check wire insulation for damage.
YesYes
IE014
Temp Over Fault (Temperature Fault). Tigo suggestion: Check ambient temperature; move or shade equipment.
YesYes
IE015
Bat Con Dir Fault (Battery Connection Fault). Tigo suggestion: Check for reversed battery input lines.
YesYes
IE016
Missed CT Fault (-). Tigo suggestion: No resolution published.
YesYes
IE017
EPS(Off-grid) Overload Fault (EPS(Off-Grid) Over Load Fault). Tigo suggestion: Switch off high-power devices on EPS panel and press ESC to restart.
YesYes
IE018
OverLoad Fault (On-Grid Mode Overload Fault). Tigo suggestion: Switch off high-power device and press ESC.
YesYes
IE019
PV Conn Dir Fault (PV Direction Fault). Tigo suggestion: Check PV input lines not reversed.
YesYes
IE020
BatPowerLow (Battery Power Low Fault). Tigo suggestion: Switch off high-power device, press ESC; charge battery above protection level.
YesYes
IE021
Low Temp (Low Temperature fault). Tigo suggestion: Check ambient temperature.
YesYes
IE023
Charger Relay Fault (Charge Relay Fault). Tigo suggestion: Press ESC to restart.
YesYes
IE024
BMS Lost (Battery Communication Fault). Tigo suggestion: Check battery-inverter comms cables.
YesYes
IE025
Inter Comms Fault (Internal Communication Fault). Tigo suggestion: Shut down PV, battery and grid; reconnect.
YesYes
IE026
Fan Fault (Fan Fault). Tigo suggestion: Check for foreign matter in fan.
YesYes
IE027
Earth Relay Fault (EPS(Off-Grid) Earth Relay Fault). Tigo suggestion: Press ESC to restart.
YesYes
IE029
RCD Fault (Residual Current Device Fault). Tigo suggestion: Check DC/AC impedance; disconnect/reconnect PV and batteries.
YesYes
IE030
EPS(Off-grid) Relay Fault (EPS(Off-Grid) Relay Failure). Tigo suggestion: Disconnect PV, grid and batteries then reconnect.
YesYes
IE031
Grid Relay Fault (Electrical Relay Failure). Tigo suggestion: Disconnect PV, grid and batteries then reconnect.
YesYes
red-and-yellow-alternating
Auto PV-Safe mode engaged by CCA (only with older MLPE such as MM-ES50 after sustained high current) - rapid-shutdown-like state.
PartlyYes
solid-red
CCA cannot connect to network or Tigo server (wrong password, firewall, weak signal) or cannot complete discovery (fewer TAPs than specified).
PartlyYes
solid-yellow
Warning: discovery not initiated, or completed with errors (TAP count not set, <75% optimisers found), or internet not allowing upload.
PartlyYes
steady-green
System OK: discovery complete, required TAPs and at least 75% of optimisers found, internet upload working.
NoYes