Solar · Error codes · Solis
ILeak-PRO01Solis · S6-EH1P L-PLUS 48 V hybrids

ILeak-PRO01 on a Solis S6-EH1P L-PLUS 48 V hybrids: Leakage current failure 01 (30 mA); 02=60 mA, 03=150 mA

Short answer

On a Solis inverter, ILeak-PRO01 means: Leakage current failure 01 (30 mA); 02=60 mA, 03=150 mA. The inverter stops until the fault clears or is reset.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Leakage current failure 01 (30 mA); 02=60 mA, 03=150 mA.

Part involved: residual current.

Likely causes:

  • Current leakage to ground; poor grounding; damaged wires.

Is it safe?

Switch the inverter off at its isolator and call an engineer.

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes

The inverter stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Restart; contact service if persists.

What you can check

  • Read the full code and message on the inverter screen or in the SolisCloud app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).

What the engineer will check

  • Check leakage to ground, grounding, wiring condition.

Who to ask for: MCS-certified solar PV installer (DC/string work) or the original installer.

Certification: Work on DC strings and inverter enclosures: competent PV installer (MCS-certified installer for warranty/SEG continuity); electrical work notifiable under Part P (England & Wales) or equivalent.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026