Solar · Error codes · Solis
ARC-Solis · S6-EH1P L-PLUS 48 V hybrids

ARC- on a Solis S6-EH1P L-PLUS 48 V hybrids: AFCI failure - DC arc detected

Short answer

On a Solis inverter, ARC- means: AFCI failure - DC arc detected. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: AFCI failure - DC arc detected.

Part involved: DC arc detection.

Likely causes:

  • Loose PV connections, damaged cable/MC4.

Is it safe?

Switch the inverter off at its isolator and call an engineer.

Does the inverter stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Installer checks and clears.

What you can check

  • Read the full code and message on the inverter screen or in the SolisCloud app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).
  • Do not touch DC cables or isolator; call your installer - arcing is a fire risk.

What the engineer will check

  • Check all PV connections tight; inspect MC4s and cable damage; AFCI settings.

Who to ask for: MCS-certified solar PV installer (DC/string work) or the original installer.

Certification: Work on DC strings and inverter enclosures: competent PV installer (MCS-certified installer for warranty/SEG continuity); electrical work notifiable under Part P (England & Wales) or equivalent.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026