BMS Lost on a SolaX Power SolaX X1-Hybrid G3: BMS Communication Lost - check if the BMS cable is loose or broken
Short answer
On a SolaX Power battery, BMS Lost means: BMS Communication Lost - check if the BMS cable is loose or broken. The battery keeps running with some functions stopped.
Reviewed 24 September 2026 · 1 source
What it means
The manual says: BMS Communication Lost - check if the BMS cable is loose or broken.
Part involved: Inverter-BMS communication (CAN/RS485).
Likely causes:
- As described in manual.
Is it safe?
| Does the battery stop? | Partly |
|---|---|
| Severity | Warning |
The battery keeps running with some functions stopped.
Resetting itself: yes if the link recovers (e.g. after battery restart).
Manual reset: restart may clear.
What you can check
- Read and note the exact code and time from the inverter display or app (screenshot).
- Check the battery is switched on and its LEDs are lit (look only).
- Check the solar/battery AC isolator and the consumer-unit breaker/RCD are ON (do not reset a breaker that trips again immediately).
- Where the SolaX manual says 'press the ESC key to restart the inverter', a homeowner can do that on the display. Steps that say 'disconnect PV+/PV-/battery' are for the installer only.
What the engineer will check
- Check BMS comms cable, pin-out and termination.
- Check battery type selection and firmware compatibility.
- Check battery DC breaker.
Who to ask for: Battery installer.
Certification: Electrician competent in electrical energy storage (BS 7671 Chapter 57; IET Code of Practice for Electrical Energy Storage Systems), ideally the MCS battery installer (MIS 3012); brand-approved installer to keep warranty.
What you might notice
Sources
- X1-Hybrid G3 User Manual (EN) ↗ · page PDF p.34-35 · Reviewed 24 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 24 September 2026