AC10M Volt FaultSolaX Power · SolaX X1-Hybrid G3

AC10M Volt Fault on a SolaX Power SolaX X1-Hybrid G3: The grid voltage is out of range for the last 10 minutes

Short answer

On a SolaX Power inverter, AC10M Volt Fault means: The grid voltage is out of range for the last 10 minutes. The inverter stops until the fault clears or is reset.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: The grid voltage is out of range for the last 10 minutes.

Part involved: AC grid protection (G98/G99 over-voltage).

Likely causes:

  • As described in manual.

Is it safe?

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes

The inverter stops until the fault clears or is reset.

Resetting itself: yes - reconnects automatically once grid voltage has been back inside limits for the reconnection time.

Manual reset: no.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Check the solar/battery AC isolator and the consumer-unit breaker/RCD are ON (do not reset a breaker that trips again immediately).
  • Note whether it happens on sunny middays (high export raises local voltage) - tell the installer/DNO.
  • Check if neighbours with solar have the same issue.
  • Where the SolaX manual says 'press the ESC key to restart the inverter', a homeowner can do that on the display. Steps that say 'disconnect PV+/PV-/battery' are for the installer only.

What the engineer will check

  • Measure grid voltage at the origin and at the inverter under export.
  • Check AC cable size / voltage rise between inverter and meter (IET PV CoP).
  • Confirm country/grid code set to UK G98 or G99 and protection settings unchanged.
  • Report persistent high supply voltage to the DNO (statutory limit 230 V +10%/-6%).

Who to ask for: PV installer / electrician; DNO for supply voltage.

Certification: Usually none (grid-side event). If persistent: installer/electrician to measure supply voltage and check settings; DNO investigates supply voltage (G98/G99 protection settings must not be changed without DNO agreement).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.