I.73 on a Viessmann One Base: Overvoltage, DC link, inverter
Short answer
On a Viessmann heat pump, I.73 means: Overvoltage, DC link, inverter. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Overvoltage, DC link, inverter.
Part involved: Overvoltage, DC link, inverter.
When it shows: System characteristics:; DC voltage in inverter intermediate circuit too high (overvoltage); Compressor temporarily off.
Likely causes:
- DC voltage in inverter intermediate circuit too high (overvoltage).
- Compressor temporarily off.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Information only |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).
Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.
What you can check
- On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
- Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
- Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
What the engineer will check
- Check the power supply for overvoltage (mains connection); put the system back into operation.
- Check the 3 phases on the inverter for symmetrical voltage supply.
- Replace inverter if necessary.
Who to ask for: Viessmann-trained heat pump engineer / qualified electrician.
Certification: Qualified electrician for work on electrical equipment (Viessmann safety instructions).
What you might notice
Sources
- Service instructions for contractors: Heat pumps in monoblock design incl. hybrid – System configuration and diagnostics (Vitocal 150-A/151-A/250-A/252-A, IDU-A, AWMOF-151/251, AquaSnap 30AWH, BI-BLOC R290) (6199893 GB 01/2026) ↗ · 6199893 GB 01/2026 (VSA00009) · page 218 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026