I.176 on a Viessmann One Base: Compressor runs with reduced output

Short answer

On a Viessmann heat pump, I.176 means: Compressor runs with reduced output. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor runs with reduced output.

Part involved: Compressor runs with reduced output.

When it shows: System characteristics: Ambient temperature at refrigerant circuit is higher than permissible operating temperature for compressor.

Likely causes:

  • Ambient temperature at refrigerant circuit is higher than permissible operating temperature for compressor.

Is it safe?

Does the heat pump stop?Not stated
SeverityInformation only
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.

What the engineer will check

  • Check the temperature in the area of the refrigerant circuit.
  • Check the inverter temperature sensor.
  • Inform the manufacturer's technical support.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).