I.131 on a Viessmann One Base: Min. evaporation temperature reached

Short answer

On a Viessmann heat pump, I.131 means: Min. evaporation temperature reached. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Min. evaporation temperature reached.

Part involved: Min. evaporation temperature reached.

When it shows: System characteristics: Insufficient heat supply.

Likely causes:

  • Insufficient heat supply.

Is it safe?

Does the heat pump stop?Not stated
SeverityInformation only
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the outdoor unit is not blocked by leaves, debris or snow.

What the engineer will check

  • Check the evaporator and fan for dirt and ice. If necessary, clean/carefully de-ice the evaporator and fan mechanically.
  • Start actuator test and function check via HMI programming unit or ViGuide. Check the function of the electronic expansion valve.
  • Check the refrigerant circuit for dirt. Flush if necessary.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

Sources

A code explains what the controller detected, not a confirmed root cause.