F.980 on a Viessmann One Base: Required flow rate for DHW heating not reached

Short answer

On a Viessmann heat pump, F.980 means: Required flow rate for DHW heating not reached. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Required flow rate for DHW heating not reached.

Part involved: Required flow rate for DHW heating not reached.

When it shows: System characteristics: No DHW heating.

Likely causes:

  • Minimum flow rate for DHW heating not reached.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199961 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the system pressure shown on the HMI "System overview" (6249162 p.35) or pressure gauge and report a low reading; make sure the filling loop is closed.

What the engineer will check

  • Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
  • Loading cylinder individually: If necessary, open closed shut-off valves and 3-way valves in the direction of DHW heating.
  • Restart the venting function via ViGuide.
  • Indoor unit individually: Check the quick-action air vent valve:.
  • Quick-action air vent valve must be permanently open.
  • Check for leaks. Replace the quick-action air vent valve if necessary.
  • Extension unit individually: Check the system pressure at the pressure gauge or via ViGuide. Top up with water if necessary.
  • Indoor unit individually: Check the cylinder loading pump. Replace if necessary.

Who to ask for: Viessmann-trained heat pump installer/service engineer.