F.927 on a Viessmann One Base: Data from energy meter 5 not available

Short answer

On a Viessmann heat pump, F.927 means: Data from energy meter 5 not available. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Data from energy meter 5 not available.

Part involved: Data from energy meter 5 not available.

When it shows: System characteristics: No information on Energy Management (EMS) available in ViGuide or app.

Likely causes:

  • Data from energy meter 5 not available.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check the software version of the energy meter. Run software update if required.
  • Check CAN bus connection to energy meter.
  • Check the settings for Energy Management (EMS) in the commissioning assistant. Adjust settings if necessary.
  • Have the identification number read out and checked by the manufacturer's technical support. See energy meter documentation.

Who to ask for: Viessmann-trained heat pump installer/service engineer.