F.914Viessmann · One Base

F.914 on a Viessmann One Base: Inverter temperature too high

Short answer

On a Viessmann heat pump, F.914 means: Inverter temperature too high. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Inverter temperature too high.

Part involved: Inverter temperature too high.

When it shows: System characteristics: Heat pump does not start.

Likely causes:

  • Inverter temperature too high.
  • Further messages: I.75 and I.121.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199961 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Isolate the system from the power supply.
  • Check inverter heat sink for dirt. Ensure heat transfer.
  • Check evaporator for unobstructed flow. If necessary, clean evaporator.
  • Check fan and fan motor bearings for damage and blockages: Turn slowly by hand. Remove any blockages. Replace fan motor if necessary.
  • Replace ODUC refrigerant circuit controller.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026