F.875 on a Viessmann One Base: Communication error with connected main appliance

Short answer

On a Viessmann heat pump, F.875 means: Communication error with connected main appliance. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Communication error with connected main appliance.

Part involved: Communication error with connected main appliance.

When it shows: System characteristics: Limited operation of the heat pump cascade.

Likely causes:

  • Communication error with (lead) heat pump (main appliance).

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check the following CAN bus connections:.
  • Connection X8.1 to X8.3 on plug 91 on HPMU electronics module.
  • Wall mounted indoor unit: Connection on device underside, 6-pole connection socket on the left, terminals 1.CAN L to 3.CAN H Floorstanding indoor unit: Terminal area ….
  • Connections to the other CAN bus subscribers.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  • Check CAN L/CAN H assignment.

Who to ask for: Viessmann-trained heat pump installer/service engineer.