F.864 on a Viessmann One Base: Defrost not completed successfully

Short answer

On a Viessmann heat pump, F.864 means: Defrost not completed successfully. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Defrost not completed successfully.

Part involved: Defrost not completed successfully.

When it shows: System characteristics:; No defrost; Compressor cannot be switched on.; Further messages may be active: F.75, F.866, F.867, F.1080, A.16, A.66, A.67, A.68, A.69.

Likely causes:

  • Defrost process aborted 10 times Further message: A.143.

Is it safe?

Does the heat pump stop?Partly
SeveritySafety lockout
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: Measures include resetting/unlocking the refrigerant circuit via HMI service menu "Reset outdoor unit" or ViGuide (engineer, password-protected; 6199893 p.118).

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the outdoor unit is not blocked by leaves, debris or snow.

What the engineer will check

  • Acknowledge messages.
  • If necessary, isolate system from power supply. Wait at least 2 min. Switch on the system.
  • Check minimum flow rate of secondary circuit.
  • Flush the system if necessary. Vent via the venting program.
  • Check all installed heating filters on the secondary side. Clean the following filters if necessary:.
  • Ball valve with filter in the outdoor unit.
  • Heating filter with magnetite separation, e.g. in the return lines on the secondary side before the inlet to the outdoor unit and before the inlet ….
  • Heating filter in heat meter.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.