F.840Viessmann · One Base

F.840 on a Viessmann One Base: Inverter phase currents to compressor asymmetrical

Short answer

On a Viessmann heat pump, F.840 means: Inverter phase currents to compressor asymmetrical. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Inverter phase currents to compressor asymmetrical.

Part involved: Inverter phase currents to compressor asymmetrical.

When it shows: System characteristics: Heat pump output demand not possible, compressor not available.

Likely causes:

  • Fluctuating power consumption on compressor, differential between min. and max. phase currents > 4 A Possible noises from compressor.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check all cables connected to compressor for correct seating, contact corrosion and damage. Replace cable if required.
  • Check phase connections for compressor for clockwise rotating field.
  • Check the winding resistances of the compressor stator for symmetry.
  • Check the 3 phase currents on the compressor. If the phase currents differ from one another, check the rotating field. Replace phase connections if necessary.
  • Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
  • Replace inverter.
  • Replace the compressor.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026