F.837 on a Viessmann One Base: Inverter electric phase connection to compressor faulty
Short answer
On a Viessmann heat pump, F.837 means: Inverter electric phase connection to compressor faulty. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Inverter electric phase connection to compressor faulty.
Part involved: Inverter electric phase connection to compressor faulty.
When it shows: System characteristics: Refrigerant circuit off: Inverter and compressor cannot be switched on.
Likely causes:
- Power supply on inverter faulty, 1 or more phases of power cable not connected.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).
Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.
What you can check
- On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
- Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
- Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
What the engineer will check
- Check all cables connected to compressor for correct seating, contact corrosion and damage. Replace cable if required.
- Check phase connections for compressor for clockwise rotating field.
- Check for correct connection of power-OFF signal:.
- Without on-site load disconnect: Connection directly to the heat pump control unit.
- With on-site load disconnect: Connection directly to the heat pump control unit and to the on-site contactor for the economy tariff.
- No power-OFF signal to power supply on heat pump control unit.
- Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
- Replace inverter.
Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.
Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).
What you might notice
Sources
- Service instructions for contractors: Heat pumps in monoblock design incl. hybrid – System configuration and diagnostics (Vitocal 150-A/151-A/250-A/252-A, IDU-A, AWMOF-151/251, AquaSnap 30AWH, BI-BLOC R290) (6199893 GB 01/2026) ↗ · 6199893 GB 01/2026 (VSA00009) · page 149 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026