F.807Viessmann · One Base

F.807 on a Viessmann One Base: Fan fault

Short answer

On a Viessmann heat pump, F.807 means: Fan fault. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Fan fault.

Part involved: Fan fault.

When it shows: System characteristics: Limited operation of the refrigerant circuit.

Likely causes:

  • Fault, fan feedback signal.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199961 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the outdoor unit is not blocked by leaves, debris or snow.

What the engineer will check

  • Check the location of the outdoor unit for vulnerability to wind. If required, take steps to protect from wind, e.g. with an air diverter in ….
  • Check fan and fan motor bearings for damage and blockages: Turn slowly by hand. Remove any blockages. Replace fan motor if necessary.
  • Check connecting cable, connections and plug-in connection P601 on ODUC refrigerant circuit controller for correct seating, contact corrosion and damage.
  • If there is voltage at plug P601 on ODUC refrigerant circuit controller, replace fan.
  • Check fuse T 3.5 A H on ODUC refrigerant circuit controller.
  • Replace ODUC refrigerant circuit controller.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.