F.75Viessmann · One Base

F.75 on a Viessmann One Base: No flow rate in the secondary circuit

Short answer

On a Viessmann heat pump, F.75 means: No flow rate in the secondary circuit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: No flow rate in the secondary circuit.

Part involved: No flow rate in the secondary circuit.

When it shows: System characteristics: The heat pump is switched off.

Likely causes:

  • No flow rate in the secondary circuit.
  • Flow sensor (if installed) faulty.
  • Secondary pump/heating circuit pump, heating/cooling circuit 1 is faulty.
  • System insufficiently vented during commissioning.
  • Frozen residual heating water in the outdoor unit in the area of the non-return valve.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the system pressure shown on the HMI "System overview" (6249162 p.35) or pressure gauge and report a low reading; make sure the filling loop is closed.

What the engineer will check

  • If this message appears after commissioning, check the float air vent valve. Restart the filling function.
  • Open shut-off valves in direction of flow. Remove any blockages. If necessary, heat the pipe to the non-return valve/ball valve with filter to thaw frozen ….
  • Check the float air vent valve. Check for refrigerant leaks (R290). Carry out the venting program. Replace the float air vent valve if necessary.
  • Clean the heating water filter. Clean the dirt separator if required.
  • Check connection of flow sensor (if installed) at X19.1 to X19.4 on the EHCU electronics module:.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026