F.744 on a Viessmann One Base: The programming unit is not compatible
Short answer
On a Viessmann heat pump, F.744 means: The programming unit is not compatible. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: The programming unit is not compatible.
Part involved: The programming unit is not compatible.
When it shows: System characteristics: HMI programming unit has limited or no functionality.
Likely causes:
- Incompatible HMI programming unit.
- CAN bus fault.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).
Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.
What you can check
- On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
- Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
- Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
What the engineer will check
- For a non-compatible HMI programming unit:.
- Inform the manufacturer's technical support. For a CAN bus error:.
- Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
- Check the CAN bus connection between the indoor unit and outdoor unit:.
- Wall mounted indoor unit: Connection on underside of appliance, 5-pin connection socket on the right, terminals 72.L to 72.H and Connection on the underside of ….
- Connection between X12.1 to X12.3 on the VCMU refrigerant circuit controller and X5.1 to X5.3 on the EHCU electronics module.
- Check wires and plugs for correct seating.
- Check connections for contact corrosion.
Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.
Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).
What you might notice
Sources
- Service instructions for contractors: Heat pumps in monoblock design incl. hybrid – System configuration and diagnostics (Vitocal 150-A/151-A/250-A/252-A, IDU-A, AWMOF-151/251, AquaSnap 30AWH, BI-BLOC R290) (6199893 GB 01/2026) ↗ · 6199893 GB 01/2026 (VSA00009) · page 139 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026