F.1336 on a Viessmann One Base: Low pressure in refrigerant circuit

Short answer

On a Viessmann heat pump, F.1336 means: Low pressure in refrigerant circuit. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low pressure in refrigerant circuit.

Part involved: Low pressure in refrigerant circuit.

When it shows: System characteristics:; Limited normal operation; High pressure and low pressure too low; Frost formation on the evaporator uneven; High temperatures in the compressor.

Likely causes:

  • Refrigerant loss.

Is it safe?

Does the heat pump stop?No
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the outdoor unit is not blocked by leaves, debris or snow.

What the engineer will check

  • Check whether all Schrader valves on the low pressure and high pressure sides are open.
  • Check the refrigerant circuit for leaks:.
  • Check refrigerant lines for mechanical damage. Refrigerant lines must be connected free of load and torque stress.
  • Check all fittings and solder joints.
  • Check all heat exchangers.
  • Check the 4-way diverter valve.
  • Check expansion valves for ice and correct function.
  • Check the compressor for damage and oil loss.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.