F.124 on a Viessmann heat pump: Short circuit, liquid gas temperature sensor, condenser

Short answer

On a Viessmann heat pump, F.124 means: Short circuit, liquid gas temperature sensor, condenser. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the One Base

The manual says: Short circuit, liquid gas temperature sensor, condenser.

Part involved: Short circuit, liquid gas temperature sensor, condenser.

When it shows: System characteristics: Refrigerant circuit off.

Likely causes:

  • Short circuit, liquid gas temperature sensor, condenser.

On the One Base Split

The manual says: Short circuit, liquid gas temperature sensor IRT.

Part involved: Short circuit, liquid gas temperature sensor IRT.

When it shows: System characteristics: Refrigerant circuit off.

Likely causes:

  • Short circuit, IRT liquid gas temperature sensor.

Is it safe?

On the One Base

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

On the One Base Split

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated per code in Viessmann document 6199961 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

On the One Base

  • Check the sensor and connection X15.1/X15.2 on the VCMU refrigerant circuit controller:.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  • Check resistor R for NTC 10 kΩ on the disconnected plug. If R < 500 Ω, replace the sensor.
  • Replace VCMU refrigerant circuit controller.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

On the One Base Split

  • Check that the sensor including spring is securely fitted.
  • Check the sensor and connection at X2.3/X2.4 on the EHCU electronics module:.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  • Check resistor R for NTC 10 kΩ on the disconnected plug. If R < 500 Ω, replace the sensor.
  • Replace EHCU electronics module.

Who to ask for: Viessmann-trained heat pump installer/service engineer.