F.1233 on a Viessmann One Base: Electrical fault, electronic expansion valve 1

Short answer

On a Viessmann heat pump, F.1233 means: Electrical fault, electronic expansion valve 1. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Electrical fault, electronic expansion valve 1.

Part involved: Electrical fault, electronic expansion valve 1.

When it shows: System characteristics: The refrigerant circuit will not start.

Likely causes:

  • Electrical fault, electronic expansion valve 1.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.

What the engineer will check

  • Check connections X8.1 to X8.5 on the VCMU refrigerant circuit controller:.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage. Replace cable if necessary.
  • Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
  • Check electronic expansion valve 1 via actuator test.
  • Check resistor R for 20 °C on disconnected plug of electronic expansion valve 1: On all 4 coils of the stator between pin 5 and ….
  • Replace the VCMU refrigerant circuit controller.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026