F.1183 on a Viessmann One Base: Fault, compressor start-up

Short answer

On a Viessmann heat pump, F.1183 means: Fault, compressor start-up. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Fault, compressor start-up.

Part involved: Fault, compressor start-up.

When it shows: System characteristics:; Output demand to heat pump not possible; Compressor not available; Further messages: A.137, A.138.

Likely causes:

  • Compressor does not start.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check all cables connected to the compressor:.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage. Replace cable if necessary.
  • Check phase connections for compressor for clockwise rotating field. Replace phase connections if necessary.
  • Check refrigerant lines for mechanical damage. Refrigerant lines must be connected free of load and torque stress.
  • Check condenser for mechanical damage. If necessary, purge the condenser.
  • Check refrigerant oil for correct viscosity and charge weight. Purge the refrigerant circuit.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026