SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
F.1174Viessmann · One Base

F.1174 on a Viessmann One Base: Forced safety shutdown, compressor - interlock input 2 active

Short answer

On a Viessmann heat pump, F.1174 means: Forced safety shutdown, compressor - interlock input 2 active. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Forced safety shutdown, compressor - interlock input 2 active.

Part involved: Forced safety shutdown, compressor - interlock input 2 active.

When it shows: System characteristics:; Output demand to heat pump not possible; Compressor not available.

Likely causes:

  • Forced safety shutdown of the compressor.

Is it safe?

Does the heat pump stop?Partly
SeveritySafety lockout
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: Measures include resetting/unlocking the refrigerant circuit via HMI service menu "Reset outdoor unit" or ViGuide (engineer, password-protected; 6199893 p.118).

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
  • Check inverter safety circuit for correct function.
  • Disconnect connection X3.1/X3.2 (STO2) from the inverter. Check for continuity. If necessary, replace high limit safety cut-out.
  • Replace inverter.
  • Unlock refrigerant circuit.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026