F.1094 on a Viessmann One Base: No flow rate in the cylinder loading system

Short answer

On a Viessmann heat pump, F.1094 means: No flow rate in the cylinder loading system. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: No flow rate in the cylinder loading system.

Part involved: No flow rate in the cylinder loading system.

When it shows: System characteristics: No DHW heating.

Likely causes:

  • No flow rate in the cylinder loading system.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199961 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the system pressure shown on the HMI "System overview" (6249162 p.35) or pressure gauge and report a low reading; make sure the filling loop is closed.

What the engineer will check

  • Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
  • Loading cylinder individually: Check the shut-off valves and 3-way valves:.
  • If necessary, open closed shut-off valves and 3way valves in the direction of DHW heating.
  • Check for leaks.
  • Indoor unit individually:.
  • Check the non-return valve on the cylinder loading pump, if installed.
  • Check the electrical connections and function of the cylinder loading pump. Replace the SLP-ADIO electronics module if necessary.
  • Flush thoroughly on the DHW side.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.