F.1082 on a Viessmann One Base: Condensing temperature during defrosting

Short answer

On a Viessmann heat pump, F.1082 means: Condensing temperature during defrosting. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Condensing temperature during defrosting.

Part involved: Condensing temperature during defrosting.

When it shows: System characteristics: Refrigerant circuit off.

Likely causes:

  • Condensing temperature during defrosting too low: Defrosting is aborted after 9 failed cycles. Max. evaporator refrigerant inlet temperature OCT and max. evaporator temperature OMT< 0 ….

Is it safe?

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated per code in Viessmann document 6199961 GB 01/2026 (VSA00009).

Manual reset: Measures include resetting/unlocking the refrigerant circuit via HMI service menu "Reset outdoor unit" or ViGuide (engineer, password-protected; 6199893 p.118).

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the outdoor unit is not blocked by leaves, debris or snow.

What the engineer will check

  • Check outdoor unit for ice. If necessary, carefully de-ice mechanically.
  • Check refrigerant circuit for damage. Top up refrigerant if necessary.
  • Check 4-way diverter valve for correct function. Replace if necessary.
  • If additional messages are present, act on them as described.
  • Unlock refrigerant circuit.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.