F.1079 on a Viessmann One Base: Flow rate repeatedly too low during defrost process

Short answer

On a Viessmann heat pump, F.1079 means: Flow rate repeatedly too low during defrost process. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Flow rate repeatedly too low during defrost process.

Part involved: Flow rate repeatedly too low during defrost process.

When it shows: System characteristics: Refrigerant circuit locked.

Likely causes:

  • Defrost fault.
  • Minimum flow rate in secondary circuit not reached.
  • Further message: A.16 and A.143 10 times.

Is it safe?

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: Measures include resetting/unlocking the refrigerant circuit via HMI service menu "Reset outdoor unit" or ViGuide (engineer, password-protected; 6199893 p.118).

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the system pressure shown on the HMI "System overview" (6249162 p.35) or pressure gauge and report a low reading; make sure the filling loop is closed.
  • Check the outdoor unit is not blocked by leaves, debris or snow.

What the engineer will check

  • Open shut-off valves in the direction of flow. Remove any blockages.
  • Clean the heating water filter. Clean the dirt separator if necessary.
  • Check the integral secondary pump/heating circuit pump in heating/cooling circuit.
  • Check the impeller. Remove the rotor if necessary. Remove dirt. Flush the system if necessary.
  • Check connection of flow sensor (if installed) at X19.1 to X19.4 on the EHCU electronics module:.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026