F.1074 on a Viessmann One Base: Pressure differential too low for circuit reversal

Short answer

On a Viessmann heat pump, F.1074 means: Pressure differential too low for circuit reversal. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Pressure differential too low for circuit reversal.

Part involved: Pressure differential too low for circuit reversal.

When it shows: System characteristics: Refrigerant circuit locked.

Likely causes:

  • Impermissible pressure fluctuations in refrigerant circuit Further message: I.129, 3 times.

Is it safe?

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: Measures include resetting/unlocking the refrigerant circuit via HMI service menu "Reset outdoor unit" or ViGuide (engineer, password-protected; 6199893 p.118).

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.

What the engineer will check

  • Check 4-way diverter valve: See F.801.
  • Check high pressure sensor: See F.1011.
  • Check low pressure sensor: See F.1012.
  • Check phases of compressor power supply for clockwise rotating field.
  • Check compressor: See F.1076.
  • Unlock refrigerant circuit.

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

Sources

A code explains what the controller detected, not a confirmed root cause.