F.1057 on a Viessmann One Base: Fault, high pressure sensor, refrigerant circuit

Short answer

On a Viessmann heat pump, F.1057 means: Fault, high pressure sensor, refrigerant circuit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Fault, high pressure sensor, refrigerant circuit.

Part involved: Fault, high pressure sensor, refrigerant circuit.

When it shows: System characteristics: Heat pump off.

Likely causes:

  • Fault, high pressure sensor.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated per code in Viessmann document 6199961 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check voltage U on EHCU electronics module:.
  • Terminals X20.1/X20.3: U = 5 V.
  • Terminal X20.2: U = 0 to 5 V.
  • Replace high pressure sensor if necessary.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.