F.1050 on a Viessmann One Base: Short circuit, temperature sensor, external heat/cooling generator 1

Short answer

On a Viessmann heat pump, F.1050 means: Short circuit, temperature sensor, external heat/cooling generator 1. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Short circuit, temperature sensor, external heat/cooling generator 1.

Part involved: Short circuit, temperature sensor, external heat/cooling generator 1.

When it shows: System characteristics: Unregulated operation of the external heat generator.

Likely causes:

  • Short circuit, boiler temperature sensor of external heat generator.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the operating program, time program and room temperature settings on the HMI.

What the engineer will check

  • Check the sensor and connection TS2.1/TS2.2 on the HIO electronics module:.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  • Check resistor R for NTC 10 kΩ on the disconnected plug. If R < 500 Ω, replace the sensor.
  • Replace HIO electronics module.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.