F.1049 on a Viessmann One Base: Fault, 3/2-way mixing valve for dual mode operation

Short answer

On a Viessmann heat pump, F.1049 means: Fault, 3/2-way mixing valve for dual mode operation. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Fault, 3/2-way mixing valve for dual mode operation.

Part involved: Fault, 3/2-way mixing valve for dual mode operation.

When it shows: System characteristics: External heat generator not ready for operation Further message: A.109 if set flow temperature is not reached within 60 min.

Likely causes:

  • Malfunction of the 3/2-way mixing valve for dual mode operation.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the system pressure shown on the HMI "System overview" (6249162 p.35) or pressure gauge and report a low reading; make sure the filling loop is closed.

What the engineer will check

  • Check configuration of external heat generator.
  • Check the following connections to the HIO electronics module:.
  • 52.1/52.2/52.4.
  • TS1.1/TS1.2.
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  • Check whether the external 3/2-way mixing valve opens and closes.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026