F.1034 on a Viessmann One Base: Communication fault, external CAN bus

Short answer

On a Viessmann heat pump, F.1034 means: Communication fault, external CAN bus. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Communication fault, external CAN bus.

Part involved: Communication fault, external CAN bus.

When it shows: System characteristics: Limited normal operation.

Likely causes:

  • Short circuit, external CAN bus.
  • Connections 91.CAN L/91.CAN H interchanged.

Is it safe?

Does the heat pump stop?No
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.

What the engineer will check

  • Turn off the ON/OFF switch on the indoor unit. Wait at least 2 min. Turn on the ON/OFF switch.
  • Check configuration for correct HPMU electronics module.
  • Check the following CAN bus connections:.
  • Connection X8.1 to X8.3 on plug 91 on HPMU electronics module.
  • Wall mounted indoor unit: 6-pole connection socket on underside of appliance on left, terminals 91.CAN L to 91.CAN H Floorstanding indoor unit: Terminal area for ….
  • Check wires and plugs for correct seating.
  • Check connections for contact corrosion.
  • Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026