Heat pumps · Error codes · Viessmann
A.83Viessmann · One Base

A.83 on a Viessmann One Base: Cylinder temperature sensor signal not plausible

Short answer

On a Viessmann heat pump, A.83 means: Cylinder temperature sensor signal not plausible. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Cylinder temperature sensor signal not plausible.

Part involved: Cylinder temperature sensor signal not plausible.

When it shows: System characteristics: Limited DHW heating.

Likely causes:

  • Cylinder temperature sensor signal not plausible.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check resistor R for NTC 10 kΩ on the disconnected plug. Replace sensor if necessary.
  • Wall mounted indoor unit: Connection on underside of the appliance, 6-pole connection socket on the right, terminals 9 and 10 (plug 5 on HPMU electronics ….
  • Floorstanding indoor unit: Connection X3.3/X3.4 (plug 5) on HPMU electronics module.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026