A.66 on a Viessmann One Base: Fault, feedback signal, secondary pump/heating circuit pump for heating/cooling circuit 1

Short answer

On a Viessmann heat pump, A.66 means: Fault, feedback signal, secondary pump/heating circuit pump for heating/cooling circuit 1. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Fault, feedback signal, secondary pump/heating circuit pump for heating/cooling circuit 1.

Part involved: Fault, feedback signal, secondary pump/heating circuit pump for heating/cooling circuit 1.

When it shows: System characteristics: Secondary pump/heating circuit pump, heating/cooling circuit 1 not running. Limited control of heating circuit pump, heating/cooling circuit 1.

Likely causes:

  • Incorrect circulation pump installed (other manufacturer) Incorrect circulation pump installed (pump type).

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the system pressure shown on the HMI "System overview" (6249162 p.35) or pressure gauge and report a low reading; make sure the filling loop is closed.
  • Check the operating program, time program and room temperature settings on the HMI.

What the engineer will check

  • Start actuator test and function check via HMI programming unit or ViGuide. Check function of the circulation pump.
  • Replace the circulation pump: Only use original parts from the manufacturer or spare parts approved by the manufacturer. A.67 Manufacturer identification, secondary pump/heating circuit pump ….
  • Replace the circulation pump: Only use original parts from the manufacturer or spare parts approved by the manufacturer.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026