A.65 on a Viessmann One Base: Dry run, heating circuit pump for heating/cooling circuit 2

Short answer

On a Viessmann heat pump, A.65 means: Dry run, heating circuit pump for heating/cooling circuit 2. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Dry run, heating circuit pump for heating/cooling circuit 2.

Part involved: Dry run, heating circuit pump for heating/cooling circuit 2.

When it shows: System characteristics: No room heating/room cooling, heating/cooling circuit 2.

Likely causes:

  • Heating circuit pump, heating/cooling circuit 2 running dry.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the system pressure shown on the HMI "System overview" (6249162 p.35) or pressure gauge and report a low reading; make sure the filling loop is closed.
  • Check the operating program, time program and room temperature settings on the HMI.

What the engineer will check

  • Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
  • Check all shut-off devices on the heating circuit side for leaks.
  • Check the quick-action air vent valve:.
  • Quick-action air vent valve must be permanently open.
  • Check for leaks. Replace the quick-action air vent valve if necessary.
  • Thoroughly flush the system.
  • Fill and vent the system using the filling and venting function (HMI programming unit or ViGuide).
  • Check the heating circuit pump for noise. Replace if necessary.

Who to ask for: Viessmann-trained heat pump installer/service engineer.