SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
A.162Viessmann · One Base

A.162 on a Viessmann One Base: Inverter overvoltage, intermediate circuit

Short answer

On a Viessmann heat pump, A.162 means: Inverter overvoltage, intermediate circuit. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Inverter overvoltage, intermediate circuit.

Part involved: Inverter overvoltage, intermediate circuit.

When it shows: System characteristics: Compressor temporarily off.

Likely causes:

  • Inverter reports overvoltage in the intermediate circuit.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check the power cable and all cables connected to the compressor for correct seating, contact corrosion and damage. Replace cable if necessary.
  • Have the parameters of the compressor checked by the manufacturer's technical support.

Who to ask for: Viessmann-trained heat pump engineer / qualified electrician.

Certification: Qualified electrician for work on electrical equipment (Viessmann safety instructions).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026