Heat pumps · Error codes · Viessmann
A.101Viessmann · One Base

A.101 on a Viessmann One Base: Hot gas temperature sensor signal not plausible

Short answer

On a Viessmann heat pump, A.101 means: Hot gas temperature sensor signal not plausible. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Hot gas temperature sensor signal not plausible.

Part involved: Hot gas temperature sensor signal not plausible.

When it shows: System characteristics: Refrigerant circuit operation impaired.

Likely causes:

  • Values for hot gas temperature in relation to hot gas pressure not plausible.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code in Viessmann document 6199893 GB 01/2026 (VSA00009).

Manual reset: User may acknowledge via HMI after noting the code (6249162 p.57); the message returns if the cause persists.

What you can check

  • On the HMI, tap the message and "?" to read the system characteristics and Viessmann's user tips; note the code (e.g. F.xxx) and text for your contractor (operating instructions 6249162 p.57).
  • Acknowledge the message once via the HMI; do not acknowledge fault messages several times in quick succession (6249162 p.58) - notify your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check high pressure sensor: With the system running, measure the voltage U from 0 to 5 V at connection X14.2/X14.3 of the VCMU refrigerant circuit ….
  • Check hot gas temperature sensor: Check resistor R for NTC 10 kΩ on the disconnected plug. Replace sensor if required. Connection: X14.9/X14.10 on the VCMU ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas certification and R290 (A3 flammable refrigerant) competence.

Certification: F-gas certificate (UK F-gas Regulations; EU 2015/2067 Cat. I cited by Viessmann) plus A3/R290 competence per EN 378-4 or IEC 60335-2-40 Annex HH (6202263 p.2).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026