SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes

Joule heat pump error codes

Joule · A niche brand in the UK. 31 codes across 2 product families, each taken from the manufacturer’s manuals. Joule technical support ↗

Find a Joule engineer →31 codes · reviewed 23 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

31 codes

CodeMeaningStops?Homeowner check?
10
Water Pressure low, < 0.8 bar
NoYes
11
Replace filter
NoYes
12
No communication with the room thermostat
YesYes
13
No communication with the boiler
YesYes
20
Filter reached end of lifespan
NoYes
30
Top tank temperature sensor error
YesYes
31
Bottom tank temperature sensor error
YesYes
32
Back up heater water heater temperature sensor error
YesYes
33
Air-In sensor error - Green Comfort Module
YesYes
34
Air-Out sensor error - Green Comfort Module
YesYes
35
Airflow sensor error - Green Comfort Module
YesYes
36
Frost protection active - Green Comfort Module
YesYes
37
Lost connection with Green Comfort Module
YesYes
38
Lost communication between ComfortZone UFH wiring centre and the Green Comfort Module
YesYes
51
Air-In sensor error
Varies by modelYes
52
Air-Out sensor error
Varies by modelYes
53
Evaporator sensor error
Varies by modelYes
54
HP Return sensor error
Varies by modelYes
55
HP Supply sensor error
Varies by modelYes
56
Hot Gas sensor error
Varies by modelYes
60
Airflow sensor error
Varies by modelYes
70
Water pressure sensor error
Varies by modelYes
71
Back up heater protection active
YesYes
80
No temperature difference across the condenser
PartlyYes
81
No temperature difference across the evaporator
PartlyYes
90
Compressor locked (repeated error 80)
YesYes
94
Compressor locked (repeated error 81)
YesYes
95
Water pressure is critically low (< 0.3 bar)
YesYes
AP2
The average central heating temperature is higher than 60C
PartlyYes
AP3
The freeze protection is active
NoYes
AP4
Pause mode - the compressor must not be started yet
PartlyYes