80Joule

80 on a Joule heat pump: No temperature difference across the condenser

Short answer

On a Joule heat pump, 80 means: No temperature difference across the condenser. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Modul-AIR exhaust air heat pump

The manual says: No temperature difference across the condenser.

On the Victorum exhaust air heat pump

The manual says: No Temp diff across Condensor.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Automatic restart after 1 hour.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.

What the engineer will check

On the Modul-AIR exhaust air heat pump

  • Manual 'possible solution': Check the circulating pump operation, possible air in the system.
  • Check water flow rate/flow switch and wiring.
  • Check strainer/magnetic filter for blockage.
  • Vent air from the system.
  • Check circulating pump operation and pipe sizing.
  • Check valves/zone valves are open.

Who to ask for: heating / plumbing heat pump installer.

Certification: None specific (unvented/G3 if cylinder work).

On the Victorum exhaust air heat pump

  • Manual 'possible solution': Check circulating pump operation or possible air in the system.
  • Check water flow rate/flow switch and wiring.
  • Check strainer/magnetic filter for blockage.
  • Vent air from the system.
  • Check circulating pump operation and pipe sizing.
  • Check valves/zone valves are open.

Who to ask for: heating / plumbing heat pump installer.

Certification: None specific (unvented/G3 if cylinder work).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.