10Joule

10 on a Joule heat pump: Water Pressure low, < 0.8 bar

Short answer

On a Joule heat pump, 10 means: Water Pressure low, < 0.8 bar. The heat pump keeps running. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Modul-AIR exhaust air heat pump

The manual says: Water Pressure low, < 0.8 bar.

On the Victorum exhaust air heat pump

The manual says: Water Pressure low (<0.8bar).

Is it safe?

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

What you can check

On the Modul-AIR exhaust air heat pump

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Joule-trained installer should check any filter or pressure action; the manual permits users only to replace the air filter.

On the Victorum exhaust air heat pump

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.

What the engineer will check

  • Manual 'possible solution': Increase water pressure.
  • Check and restore system pressure via filling loop.
  • Check for leaks and expansion vessel charge.
  • Check water pressure sensor/switch and wiring.

Who to ask for: heating / plumbing heat pump installer.

Certification: None specific.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026