81 on a Joule heat pump: No temperature difference across the evaporator

Short answer

On a Joule heat pump, 81 means: No temperature difference across the evaporator. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Modul-AIR exhaust air heat pump

The manual says: No temperature difference across the evaporator.

On the Victorum exhaust air heat pump

The manual says: No Temp diff across Evaporator.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Automatic restart after 1 hour.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

What the engineer will check

On the Modul-AIR exhaust air heat pump

  • Manual 'possible solution': Check the fan operation, possible blockage in the duct system.
  • Check fan motor, wiring and PWM signal.
  • Check fan blade for obstruction or ice.

Who to ask for: heat pump engineer.

Certification: Electrical competence.

On the Victorum exhaust air heat pump

  • Manual 'possible solution': Check fan operation or a possible blockage in the duct system.
  • Check fan motor, wiring and PWM signal.
  • Check fan blade for obstruction or ice.

Who to ask for: heat pump engineer.

Certification: Electrical competence.