52 on a Joule heat pump: Air-Out sensor error

Short answer

On a Joule heat pump, 52 means: Air-Out sensor error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Modul-AIR exhaust air heat pump

The manual says: Air-Out sensor error.

On the Victorum exhaust air heat pump

The manual says: Air Out sensor error.

Is it safe?

On the Modul-AIR exhaust air heat pump

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Installer override required.

On the Victorum exhaust air heat pump

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.

What the engineer will check

  • Manual 'possible solution': Check sensor. Replace if necessary.
  • Check the named sensor/probe connection at the PCB (loose/oxidised plug).
  • Measure sensor resistance against the manufacturer table and replace if faulty.
  • Check controller/PCB if sensor is good.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.