iDM Energiesysteme heat pump error codes

iDM Energiesysteme · No longer sold new in the UK. 171 codes across 1 product family, each taken from the manufacturer’s manuals. iDM Energiesysteme technical support ↗

Find a iDM Energiesysteme engineer →171 codes · reviewed 23 September 2026

Search within brand

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

171 codes

CodeMeaningStops?Homeowner check?
020
Heat pump flow maximum temperature: Heat pump flow temperature is above the set maximum temperature.
YesYes
021
Heat pump flow minimum temperature: Heat pump flow temperature is below the set minimum temperature.
YesYes
022
Low pressure fault: The low-pressure monitor has switched the heat pump off (< 3 times in 24 h).
YesYes
023
Low pressure fault - lockout: The low-pressure monitor has switched the heat pump off (> 3 times in 24 h). The heat pump is no longer operated. After fault 023 the unit may be unlocked at most once!
YesYes
024
High pressure fault: The high-pressure monitor has switched the heat pump off (< 3 times in 24 h).
YesYes
025
High pressure fault - lockout: The high-pressure monitor has switched the heat pump off (> 3 times in 24 h). The heat pump is no longer operated.
YesYes
026
Flow monitoring / pressure monitoring: The flow switch on groundwater systems has switched the heat pump off (< 3 times in 24 h).
YesYes
027
Flow lockout / pressure monitoring - lockout: The flow switch on groundwater systems has switched the heat pump off (> 3 times in 24 h). The heat pump is no longer operated.
YesYes
028
Soft starter 1 (see LED): Soft-starter fault (< 5 times in 24 h). The type of fault is indicated on the soft starter.
YesYes
029
Soft starter 1 - lockout: Soft-starter fault (> 5 times in 24 h). The heat pump is no longer operated.
YesYes
030
Motor protection heat source pump: The motor protection of the heat source (brine/well) pump has tripped (< 5 times in 24 h).
YesYes
031
Motor protection heat source pump - lockout: The motor protection of the heat source pump has tripped (> 5 times in 24 h). The heat pump is no longer operated.
YesYes
032
Maximum defrost time exceeded: The maximum defrost time was exceeded.
Not statedYes
033
Minimum condenser temperature undershot: The heat pump was switched off because the minimum condenser temperature was undershot.
YesYes
034
Fan fault: Fault contact of the fan electronics has responded (< 3 times in 24 h).
YesYes
035
Minimum heat storage temperature undershot: Heat storage (buffer) temperature required for defrosting was undershot.
PartlyYes
036
Electric heating element overheating: Safety temperature limiter (STB) of the electric heater has tripped.
PartlyYes
037
Charging pump fault: Fault contact of the charging pump has tripped.
YesYes
038
Fan fault - lockout: Fault contact of the fan electronics has tripped (> 3 times in 24 h). The heat pump is no longer operated.
YesYes
042
Hot gas temperature too low: Hot gas temperature is lower than condensing temperature + 10°C. Delay 7 min.
YesYes
043
Hot gas temperature too low - lockout: The heat pump was switched off due to too low hot gas temperature (> 5 times in 24 h).
YesYes
044
Flow monitoring heating side: The flow monitor on the heating side has responded. Flow is monitored in heating, cooling and defrost operation.
YesYes
046
Hot gas temperature too high: Hot gas temperature is higher than 135°C (< 5 times in 24 h).
YesYes
047
Hot gas temperature too high - lockout: The heat pump was switched off due to too high hot gas temperature (> 5 times in 24 h). The heat pump is no longer operated.
YesYes
050
Dew point monitor responded: Dew point monitor has responded (flow temperature adjustment).
NoYes
051
Dew point monitor permanently responded: Dew point monitor permanently responded - cooling function is blocked.
PartlyYes
060
Heat source temperature: The measured heat source outlet temperature is below the minimum heat source temperature.
YesYes
061
Heat source temperature approaching critical value: Heat source outlet temperature reaches a critical value (min. heat source temperature + 2 K).
NoYes
062
Winding protection: The compressor winding protection has tripped (< 3 times in 24 h).
YesYes
063
Winding protection - lockout: The compressor winding protection has tripped (> 3 times in 24 h). The heat pump is no longer operated.
YesYes
067
Heat source temperature - lockout: The minimum heat source outlet temperature was undershot (> 5 times in 24 h). The heat pump is no longer operated.
YesYes
070
EIB/KNX module fault: No EIB-KNX module is connected to the Navigator main board or the module is not programmed (shown 30 s after parameterisation).
NoYes
074
Soft starter 2 (see LED): Soft-starter fault on the second compressor; type of fault shown on the soft starter.
PartlyYes
075
Soft starter 2 - lockout: Soft-starter fault on the second compressor (> 5 times in 24 h). The heat pump is no longer operated.
YesYes
080
Summary fault stage 1: Compressor 1 is switched off - check soft starter.
PartlyYes
081
Summary fault stage 1 - lockout: Compressor 1 is no longer operated.
PartlyYes
082
Summary fault stage 2: Compressor 2 is switched off - check soft starter.
PartlyYes
083
Summary fault stage 2 - lockout: Compressor 2 is no longer operated.
PartlyYes
084
Summary fault stage 3: Compressor 3 is switched off - check soft starter.
PartlyYes
085
Summary fault stage 3 - lockout: Compressor 3 is no longer operated.
PartlyYes
086
Summary fault stage 4: Compressor 4 is switched off - check soft starter.
PartlyYes
087
Summary fault stage 4 - lockout: Compressor 4 is no longer operated.
PartlyYes
088
Expansion valve 1: Expansion valve driver, refrigerant circuit 1.
Not statedYes
089
Expansion valve 2: Expansion valve driver, refrigerant circuit 2.
Not statedYes
090
Central unit 1 not online: Communication problem - master board A1 not found.
Not statedYes
091
Central unit 2 not online: Communication problem - slave board A7 not found.
Not statedYes
095
Operating limit exceeded: Operation outside (above) the compressor envelope: at the current evaporating temperature the condensing temperature is outside the operating range.
Not statedYes
096
Operating limit MOP: Operation outside the compressor envelope: at the current condensing temperature the evaporating temperature is outside the operating range.
Not statedYes
100
Sensor fault: Outdoor sensor (B32) - short circuit.
Not statedYes
101
Sensor fault: Outdoor sensor (B32) - open circuit (break).
Not statedYes
102
Sensor fault: Heat pump flow sensor (B33) - short circuit.
Not statedYes
103
Sensor fault: Heat pump flow sensor (B33) - open circuit (break).
Not statedYes
104
Sensor fault: HGL flow sensor (B35) - short circuit.
Not statedYes
105
Sensor fault: HGL flow sensor (B35) - open circuit (break).
Not statedYes
106
Sensor fault: Heat source outlet sensor (B36) - short circuit.
Not statedYes
107
Sensor fault: Heat source outlet sensor (B36) - open circuit (break).
Not statedYes
108
Sensor fault: Heat storage/buffer tank sensor (B38) - short circuit.
Not statedYes
109
Sensor fault: Heat storage/buffer tank sensor (B38) - open circuit (break).
Not statedYes
110
Sensor fault: Cold storage tank sensor (B40) - short circuit.
Not statedYes
111
Sensor fault: Cold storage tank sensor (B40) - open circuit (break).
Not statedYes
112
Sensor fault: DHW cylinder sensor bottom (B41) - short circuit.
Not statedYes
113
Sensor fault: DHW cylinder sensor bottom (B41) - open circuit (break).
Not statedYes
114
Sensor fault: Fresh water station sensor (B42) - short circuit.
Not statedYes
115
Sensor fault: Fresh water station sensor (B42) - open circuit (break).
Not statedYes
116
Sensor fault: Flow sensor heating circuit A (B51) - short circuit.
Not statedYes
117
Sensor fault: Flow sensor heating circuit A (B51) - open circuit (break).
Not statedYes
118
Sensor fault: Flow sensor heating circuit B (B52) - short circuit.
Not statedYes
119
Sensor fault: Flow sensor heating circuit B (B52) - open circuit (break).
Not statedYes
120
Sensor fault: Room sensor heating circuit A (B61) - short circuit.
Not statedYes
121
Sensor fault: Room sensor heating circuit A (B61) - open circuit (break).
Not statedYes
122
Sensor fault: Room sensor heating circuit B (B62) - short circuit.
Not statedYes
123
Sensor fault: Room sensor heating circuit B (B62) - open circuit (break).
Not statedYes
124
Sensor fault: Hot gas sensor (B71) - short circuit.
Not statedYes
125
Sensor fault: Hot gas sensor (B71) - open circuit (break).
Not statedYes
126
Sensor fault: Room humidity sensor (B31) - short circuit.
Not statedYes
127
Sensor fault: Room humidity sensor (B31) - open circuit (break).
Not statedYes
128
Sensor fault: Low pressure sensor - short circuit.
Not statedYes
129
Sensor fault: Low pressure sensor - open circuit (break).
Not statedYes
130
Sensor fault: Flow sensor heating circuit C (B53) - short circuit.
Not statedYes
131
Sensor fault: Flow sensor heating circuit C (B53) - open circuit (break).
Not statedYes
132
Sensor fault: Flow sensor heating circuit D (B54) - short circuit.
Not statedYes
133
Sensor fault: Flow sensor heating circuit D (B54) - open circuit (break).
Not statedYes
134
Sensor fault: Room sensor heating circuit C (B63) - short circuit.
Not statedYes
135
Sensor fault: Room sensor heating circuit C (B63) - open circuit (break).
Not statedYes
136
Sensor fault: Room sensor heating circuit D (B64) - short circuit.
Not statedYes
137
Sensor fault: Room sensor heating circuit D (B64) - open circuit (break).
Not statedYes
138
Sensor fault: Flow sensor heating circuit E (B55) - short circuit.
Not statedYes
139
Sensor fault: Flow sensor heating circuit E (B55) - open circuit (break).
Not statedYes
140
Sensor fault: Flow sensor heating circuit F (B56) - short circuit.
Not statedYes
141
Sensor fault: Flow sensor heating circuit F (B56) - open circuit (break).
Not statedYes
142
Sensor fault: Flow sensor heating circuit G (B57) - short circuit.
Not statedYes
143
Sensor fault: Flow sensor heating circuit G (B57) - open circuit (break).
Not statedYes
144
Sensor fault: Room sensor heating circuit E (B65) - short circuit.
Not statedYes
145
Sensor fault: Room sensor heating circuit E (B65) - open circuit (break).
Not statedYes
146
Sensor fault: Room sensor heating circuit F (B66) - short circuit.
Not statedYes
147
Sensor fault: Room sensor heating circuit F (B66) - open circuit (break).
Not statedYes
148
Sensor fault: Room sensor heating circuit G (B67) - short circuit.
Not statedYes
149
Sensor fault: Room sensor heating circuit G (B67) - open circuit (break).
Not statedYes
150
Sensor fault: Suction gas sensor evaporator outlet (B79) - short circuit.
Not statedYes
151
Sensor fault: Suction gas sensor evaporator outlet (B79) - open circuit (break).
Not statedYes
152
Sensor fault: Low pressure transmitter (B78) - short circuit.
Not statedYes
153
Sensor fault: Low pressure transmitter (B78) - open circuit (break).
Not statedYes
154
Sensor fault: Solar collector sensor (B73) - short circuit.
Not statedYes
155
Sensor fault: Solar collector sensor (B73) - open circuit (break).
Not statedYes
156
Sensor fault: Solar charging sensor (B74) - short circuit.
Not statedYes
157
Sensor fault: Solar charging sensor (B74) - open circuit (break).
Not statedYes
158
Sensor fault: Solar collector return sensor (B75) - short circuit.
Not statedYes
159
Sensor fault: Solar collector return sensor (B75) - open circuit (break).
Not statedYes
160
Sensor fault: Solar heat source reference sensor (B76) - short circuit.
Not statedYes
161
Sensor fault: Solar heat source reference sensor (B76) - open circuit (break).
Not statedYes
162
Sensor fault: Intake air sensor (B37) - short circuit.
Not statedYes
163
Sensor fault: Intake air sensor (B37) - open circuit (break).
Not statedYes
164
Sensor fault: Air heat exchanger sensor (B72) - short circuit.
Not statedYes
165
Sensor fault: Air heat exchanger sensor (B72) - open circuit (break).
Not statedYes
166
Sensor fault: High pressure transmitter (B86) - short circuit.
Not statedYes
167
Sensor fault: High pressure transmitter (B86) - open circuit (break).
Not statedYes
168
Sensor fault: Liquid line sensor (B87) - short circuit.
Not statedYes
169
Sensor fault: Liquid line sensor (B87) - open circuit (break).
Not statedYes
170
Sensor fault: Heat pump return sensor (B34) - short circuit.
Not statedYes
171
Sensor fault: Heat pump return sensor (B34) - open circuit (break).
Not statedYes
172
Sensor fault: Heat source inlet sensor (B43) - short circuit.
Not statedYes
173
Sensor fault: Heat source inlet sensor (B43) - open circuit (break).
Not statedYes
178
Sensor fault: Charging sensor (B45) - short circuit.
Not statedYes
179
Sensor fault: Charging sensor (B45) - open circuit (break).
Not statedYes
196
Sensor fault: DHW cylinder sensor top (B48) - short circuit.
Not statedYes
197
Sensor fault: DHW cylinder sensor top (B48) - open circuit (break).
Not statedYes
200
Operating limit reached: Operation outside the operating range on air-source heat pumps.
Not statedYes
221
Low pressure fault 2 (second refrigerant circuit): The low pressure switch has switched the heat pump off (< 3 times in 24 h).
YesYes
231
Low pressure fault 2 - lockout (second refrigerant circuit): The low pressure switch has switched the heat pump off (> 3 times in 24 h). The heat pump is no longer operated.
YesYes
236
Safety defrost interval 0.1-0.5 set: The safety defrost interval is set to 0.1-0.5 h.
NoYes
237
Charging pump fault in bivalent operation: Fault contact of the charging pump tripped during operation of the bivalent (second) heat generator.
PartlyYes
241
High pressure fault 2 (second refrigerant circuit): The high pressure switch has switched the heat pump off.
YesYes
244
Flow monitoring heating side in bivalent operation: Works like fault 44 but acts on the bivalent generator when the charging pump is configured "YES"; heating-side flow monitor responded.
PartlyYes
251
High pressure fault 2 - lockout (second refrigerant circuit): The high pressure switch has switched the heat pump off (> 3 times in 24 h). The heat pump is no longer operated.
YesYes
270
Stages blocked long-term: Triggered when all compressor stages have been blocked for more than 10 hours; leads to a summary fault so the bivalent generator is available above the bivalence point.
YesYes
271
Bivalent generator manually activated: Information that the bivalent (backup) generator was manually activated - reminder to switch it off to avoid high running costs.
NoYes
272
Bivalent operation with reduced temperature: Bivalent generator active due to a summary fault: temperature levels reduced (ECO) and no DHW production until "Bivalent only" operating mode is selected. Warning: increased heating costs.
PartlyYes
280
Collector maximum temperature: Solar collector maximum temperature exceeded; resets automatically when it falls below.
NoYes
281
DHW cylinder maximum temperature: DHW cylinder maximum temperature exceeded; resets automatically.
PartlyYes
282
Heat storage maximum temperature: Maximum buffer temperature exceeded; resets automatically.
PartlyYes
283
Heat source maximum temperature: Maximum heat source temperature exceeded; resets automatically.
PartlyYes
284
Solar module not present: Solar control configured but no CAN-bus communication with the solar module.
NoYes
301
Boost function - temperature not reached: Boost temperature not reached or DHW cylinder temperature higher than 85°C.
NoYes
302
Legionella function - temperature not reached: Legionella temperature not reached or DHW cylinder temperature higher than 85°C.
NoYes
500
Outdoor unit intake sensor defective: Intake (air) sensor in the outdoor unit defective.
Not statedYes
501
Outdoor unit suction gas sensor defective: Suction gas sensor in the outdoor unit defective.
Not statedYes
502
Outdoor unit hot gas sensor defective: Hot gas sensor in the outdoor unit defective.
Not statedYes
503
Outdoor unit low pressure sensor defective: Low pressure sensor in the outdoor unit defective.
Not statedYes
504
Outdoor unit high pressure sensor defective: High pressure sensor in the outdoor unit defective.
Not statedYes
505
Outdoor unit high pressure: Outdoor unit high pressure fault.
YesYes
506
Outdoor unit low pressure: Outdoor unit low pressure fault.
YesYes
507
Hot gas temperature: Hot gas temperature outside the operating limits.
Not statedYes
508
Differential pressure too low: Differential pressure between low and high pressure side too small.
Not statedYes
509
Outdoor unit start-up error: 5 unsuccessful start attempts.
YesYes
510
Operating limit exceeded (outdoor unit): Outside the operating range for more than 5 minutes.
Not statedYes
511
Superheat too low: Too low or negative superheat.
Not statedYes
512
MOP fault: Maximum operating pressure exceeded.
Not statedYes
513
Suction gas temperature too low: Suction gas temperature too low.
Not statedYes
514
EEV control: Control problem with electronic expansion valve.
Not statedYes
515
Inverter communication fault: Fault between outdoor board and inverter.
YesYes
516
Outdoor unit communication: Communication fault on the Modbus link between indoor unit and outdoor unit.
YesYes
517
Inverter fault: The inverter has a fault.
YesYes
520
Outdoor unit software: Wrong software on the outdoor unit or wrong software loaded.
YesYes
521
Timeout inputs/outputs: Carel board cannot establish a bus connection.
Not statedYes
522
Timeout converter: Converter/inverter cannot establish a bus connection.
Not statedYes
523
Timeout fan: Fan cannot establish a bus connection.
Not statedYes
524
Outdoor unit emergency stop C1: Outdoor unit emergency stop refrigerant circuit 1.
YesYes
525
Outdoor unit emergency stop C2: Outdoor unit emergency stop refrigerant circuit 2.
YesYes
526
Outdoor unit emergency stop C1 - lockout: Outdoor unit emergency stop refrigerant circuit 1 - lockout.
YesYes
527
Outdoor unit emergency stop C2 - lockout: Outdoor unit emergency stop refrigerant circuit 2 - lockout.
YesYes
530
Inverter fault - lockout: The inverter is no longer operated (> 10 times in 24 h). The heat pump is no longer operated.
YesYes