H99 on a Dimplex LA MI inverter outdoor air-to-water: Poor water flow during defrost (anti-freezing protection of indoor heat exchanger)

Short answer

On a Dimplex heat pump, H99 means: Poor water flow during defrost (anti-freezing protection of indoor heat exchanger). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Poor water flow during defrost (anti-freezing protection of indoor heat exchanger).

Part involved: Refrigerant liquid temperature sensor / flow.

When it shows: During anti-freezing control in defrost, refrigerant liquid temperature < 0C.

Likely causes:

  • Poor flow during defrost.
  • Refrigerant charge incorrect.
  • Liquid temperature sensor misreading.
  • Main water PCB.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

Manual reset: Clear via control panel per Dimplex article (method shown as image).

What you can check

  • Check the heating system pressure gauge reads about 1.0-1.5 bar.
  • Note the code and contact the installer or Dimplex service.

What the engineer will check

  • Isolate the heat pump from mains before any work.
  • Flow checks as H62.
  • Weigh out refrigerant charge (F-Gas).
  • Check CN-TH1 pins 3&4 probe resistance.

Who to ask for: refrigeration / heat pump service engineer.

Certification: F-Gas (refrigerant handling) certification for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026