F20Dimplex

F20 on a Dimplex heat pump: Compressor overheating protection activated

Short answer

On a Dimplex heat pump, F20 means: Compressor overheating protection activated. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

The manual says: Compressor overheating protection activated.

Part involved: Compressor tank temperature sensor.

When it shows: Compressor tank temperature above 112C.

Likely causes:

  • Faulty compressor tank temperature sensor.
  • 2/3-way valve closed.
  • Refrigerant shortage (leak).
  • Clogged expansion valve or strainer.
  • Faulty refrigerant PCB.
  • Faulty compressor.

On the WPM heat pump manager platform (error-code grouping)

The manual says: Defrost: defrosting of the air-to-water heat pump could not be initiated or could not be ended correctly. There is a wide range of possible causes.

Part involved: Defrost control / reverse-cycle valve / flow.

When it shows: Flow temperature <18C at defrost: defrost halted, retried after 15 min; second failure activates fault, compressor blocked, 2nd heat generator enabled (GDHV).

Likely causes:

  • Heating water flow rate too low.
  • Heating water pressure too low / air in system.
  • Flow temperature below 18C so defrost aborts twice (GDHV).
  • Flow/return spread >= 12K or negative (GDHV).
  • Insufficient system volume/buffer, cold screed at first start (GDHV).

Is it safe?

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Clear via control panel per Dimplex article (method shown as image).

On the WPM heat pump manager platform (error-code grouping)

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: After rectifying the fault the heat pump can be restarted; switching off the control voltage also acknowledges the fault (WPM Touch p.54). On text-display WPMs press Esc to acknowledge (EconPlus EN-16).

Manual reset: Acknowledge after rectification.

What you can check

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

  • Note the code and contact the installer or Dimplex service.

On the WPM heat pump manager platform (error-code grouping)

  • Check the outdoor unit is not blocked by snow or debris.
  • Check the heating system pressure gauge reading (typically 1.0-1.5 bar).
  • Note the fault code, the heat pump model (type plate) and controller software version shown in operating data, and contact the installer/Dimplex service.

What the engineer will check

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

  • Isolate the heat pump from mains before any work.
  • Check CN-TANK sensor resistance.
  • Leak check / charge (F-Gas).
  • Check expansion valve X-2511026.

Who to ask for: refrigeration / heat pump service engineer.

Certification: F-Gas (refrigerant handling) certification for any refrigerant-circuit work.

On the WPM heat pump manager platform (error-code grouping)

  • Check heating water flow rate vs nominal.
  • Check heating water pressure and air.
  • Check flow and return temperatures during defrost.
  • Check strainer/magnetic filter.
  • Hot-gas-defrost models: refrigerant engineer.

Who to ask for: heat pump service engineer.

Certification: F-Gas (refrigerant handling) certification for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026