F23 on a Dimplex heat pump: DC peak detection - system stopped to protect itself

Short answer

On a Dimplex heat pump, F23 means: DC peak detection - system stopped to protect itself. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

The manual says: DC peak detection - system stopped to protect itself.

Part involved: IPM DC peak sensing circuitry.

When it shows: Outdoor DC current above 40.1+/-5.0 A (LA6/9MI) or 44.7+/-5.0 A (LA12/16MI); 7 times.

Likely causes:

  • Faulty main refrigerant PCB.
  • Faulty compressor.

On the WPM heat pump manager platform (error-code grouping)

The manual says: Compressor load: incorrect direction of rotation, phase failure, compressor start-up too long, compressor operating current undervoltage too high, soft starter overtemperature, incorrect mains frequency.

Part involved: Compressor, soft starter/inverter, supply.

Likely causes:

  • Incorrect direction of rotation (phase sequence).
  • Phase failure.
  • Compressor start-up too long.
  • Undervoltage / operating current.
  • Soft starter overtemperature.
  • Incorrect mains frequency.

Is it safe?

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Clear via control panel per Dimplex article (method shown as image).

On the WPM heat pump manager platform (error-code grouping)

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: After rectifying the fault the heat pump can be restarted; switching off the control voltage also acknowledges the fault (WPM Touch p.54). On text-display WPMs press Esc to acknowledge (EconPlus EN-16).

Manual reset: Acknowledge after rectification.

What you can check

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

  • Note the code and contact the installer or Dimplex service.

On the WPM heat pump manager platform (error-code grouping)

  • Note the fault code, the heat pump model (type plate) and controller software version shown in operating data, and contact the installer/Dimplex service.

What the engineer will check

On the LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

  • Isolate the heat pump from mains before any work.
  • Check refrigerant PCB.
  • Check compressor windings.

Who to ask for: refrigeration / heat pump service engineer.

Certification: F-Gas (refrigerant handling) certification for any refrigerant-circuit work.

On the WPM heat pump manager platform (error-code grouping)

  • Check rotary field (phase sequence).
  • Check supply voltage.
  • Check soft starter/inverter.
  • Inform after-sales service.

Who to ask for: electrical / heat pump service engineer.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026